Modular I/O Module Qmix I/O-B

I/O Modules

Modular I/O Module Qmix I/O-B

Modular I/O module with customized I/O Configuration

The Qmix I/O module integrates the Beckhoff bus terminals into the Qmix / neMESYS system and thereby extends it by a multitude of analog and digital inputs and outputs. The module’s terminal configuration can be customized and adapted to any application.

The terminal system makes it possible to connect or remove signal lines and external sensors (pressure, temperature, flow rate) very simply and quickly.

Technical Data

Many of the existingBeckhoff bus terminals can be used, such as:

Our sales team would be happy to support you with the configuration of your I/O module.


Other products you may find interesting

QmixElements I/O Plugin Screenshot

QmixElements I/O-Plugin

All I/O Channels at a Glance

The QmixElements I/O plugin enables fast and easy access to all analog and digital in- and output channels in your Qmix system. You can select the description, scaling, the icon and the unit for each channel. This lets you adapt the display of channels to your application in the optimum way.

Highlights

  • Individual description and scaling (factor & offset) for each channel
  • Real-time recording of sensor data
  • Script functions for the automation of processes

QmixElements I/O-Plugin Scripting

Automating Processes and Actuating External Devices

Triggering Events, Converting measurement values, Monitoring measuring ranges…

Like all other devices, analog and digital I/O channels are integrated into the QmixElements scripting system through the respective scripting functions. You can load analog sensor values or send analog signals. You can trigger certain processes through external signals or synchronize your process with external devices using trigger signals, thanks to the script system. Do you want to control the flow rate of a pump in real time, using an analog input signal? You can program that too in just a few minutes, through drag&drop.


Process data plot with recorded sensor values

Recording Sensor Values in Real-Time

Visualize, Analyze, Optimize…

In QmixElements you can record the values of all analog and digital inputs and outputs in the form of curves or CSV-files. This lets you visualize temporal changes of process data or connected sensors (pressure, temperature, etc.) live and in real-time. You can configure the recording through drag & drop and save diagrams in various different formats (PNG, JPG, PDF…). Using CSV-files, recorded measurement values can be analyzed or graphically processed conveniently in Excel or any other analysis program of your choice.


QmixElements Software

QmixElements Software

Laboratory automation platform

The QmixElements software is a comprehensive, plugin-based, modular software solution for the control of all cetoni devices via a common graphical user interface. The software consists of a core that provides the basic features and services, such as the application window, the event log or the tool bar.

Qmix SDK Analog I/O Library

Windows 32-Bit / 64-Bit DLLs

You can read analog inputs of Qmix I/O modules, analog pressure measuring inputs of the Qmix P modules or the analog inputs of neMESYS syringe pumps with one uniform interface used across all devices – the analog I/O library. All functions are supplied through a Windows DLL (32-bit / 64-bit), enabling simple and inexpensive integration into any 32 or 64-bit Windows development environment supporting the use of DLLs.

Some of the things you can do:

  • Write analog outputs
  • Read analog inputs
  • Configure the software scaling of measuring parameters

Qmix SDK Analog I/O Library LabVIEW VIs

Qmix SDK Analog I/O LabVIEW Kit

Full LabVIEW Integration

The LabVIEW kit lets you integrate the Qmix SDK analog I/O library into your LabVIEW environment with minimal effort. You will be provided with a selection of finished VIs to access analog inputs and outputs of Qmix modules.

Highlights

  • Clearly laid out grouping and color coding of VIs according to their function
  • Can be used with all other Qmix SDK libraries (pump, valve, motion control...)
  • LabVIEW-conformant troubleshooting
  • Sample VIs for quicker introduction
  • Supports 32 and 64 bit LabVIEW versions

Qmix SDK Digital I/O Library

Windows 32-Bit / 64-Bit DLLs

If you want to work with digital input and outputs, the digital I/O library is the perfect solution for you. It lets you access digital I/Os of Qmix I/O modules or digital inputs of neMESYS dosing modules as well as neMAXYS axis systems, for example. All functions are provided through a Windows DLL (32-bit / 64-bit), enabling simple and inexpensive integration into any 32- or 64-bit development environment supporting the use of DLLs.

You will receive functions for:

  • Reading digital inputs
  • Setting digital outputs

Qmix SDK Digital I/O Library LabVIEW VIs

Qmix SDK Digital I/O LabVIEW Kit

Full LabVIEW Integration

The Qmix SDK digital I/O LabVIEW kit is a full LabVIEW library, including all VIs for accessing digital inputs and outputs of neMESYS and Qmix modules. In combination with the other Qmix SDK LabVIEW libraries, you can truly integrate all cetoni devices into your LabVIEW applications.

Highlights

  • Clearly laid out grouping and color coding of VIs according to their function
  • Can be used with all other Qmix SDK libraries (pump, valve, motion control...)
  • LabVIEW-conformant troubleshooting
  • Sample VIs for quicker introduction
  • Supports 32- and 64 bit LabVIEW versions

Qmix SDK

Qmix Software Development Kit (SDK)

For integration of cetoni devices into custom applications

The Qmix SDK is a powerful software package that allows developers to integrate their Qmix system and its various modules into their applications. Central to the Qmix SDK are device-specific libraries that provide the programming interface (APIs) for each Qmix module (neMESYS pumps, rotAXYS and neMAXYS positioning systems, Qmix IO, etc.).

Mechanical Data

Dimensions (L x W x H) 310 x 100 x 76 mm
Weight 1.1 kg (without modules)
Max. Number of Modules 15 (12 mm)

Interfaces

Interfaces depending on mounted modules
Max. Number of Analog Inputs 40
Max. Number of Analog Outputs 40
Max. Number of Digital Inputs 64
Max. Number of Digital Outputs 64

Electrical Data

Supply Voltage 24 V DC
Max. Current 7.5 A
Power Consumption load dependent (180 W max)

Environment

Operating Temperature 0°C ~ 50°C
Storage Temperature -20°C ~ 75°C
Operating Humidity 20% ~ 90%, non-condensing
Operating Humidity 20% ~ 90%, non-condensing